Adjusting the Separation Roller Gap

If double feed should occur too often, adjust the Separation Roller gap
according to the following procedure.
A
Pull up the Adjustment Dial Cover.
B
Adjust the Adjustment Dial.
Turn the Adjustment Dial clockwise 3 clicks (to the direction in
which the number decreases) to narrow the Separation Roller
Gap. If documents are not fed after the above operation, turn the
Adjustment Dial counterclockwise 1 click (to the direction in
which the number increases) to widen the Separation Roller Gap.
C
Close the Adjustment Dial Cover.
Adjustment Dial
Turn the dial to the left to
widen the gap, and turn it
to the right to narrow the
gap.
76
CAUTION
Do not use the Adjustment Dial any other time except when adjusting
the Separation Roller gap. Turning the Adjustment Dial too much may
damage the scanner.