8) Remove the coil spring
site side using the same procedure as
above.
Figure 3-610
9) When both coil springs are removed from
the front shaft, close the upper unit. To
prevent collision with the feed surface,
paper or a sheet should be placed be-
tween the upper unit and the base unit.
Note: If the damper is removed when the
upper unit is open, the upper unit closes
under their own weight, causing danger.
Figure 3-611
COPYRIGHT © CANON ELECTRONICS INC. 2008
1
on the oppo-
CANON DR-X10C FIRST EDITION
CHAPTER 3 DISASSEMBLY & REASSEMBLY
10)
Remove 4 screws
remove the holding plate (right)
Then remove 3 screws
remove the hinge
and coil spring
7
Remove 2 screws
move the support plate
guide
10
.
Figure 3-612
1
(TP head) and
2
.
3
(TP head) and
4
, arm
5
, shaft
.
8
(TP head) and re-
9
and shaft