CHAPTER 3 DISASSEMBLY & REASSEMBLY

7. Tray Drive Unit

1) Remove the pickup tray unit and tray de-
tection PCB.
(Page 3-6), (Page 3-17)
2) Remove the registration roller.
(Page 3-25)
3) Remove 2 cables connected to the tray
drive unit from the relay connector. Then,
remove the screws
Then, remove the stop rings
outside both side plates and remove the
bearing. Slide the gear
the pin.
Figure 3-314
3-18
1
(with washers).
2
located
3
and remove
COPYRIGHT © CANON ELECTRONICS INC. 2008
4) Rotate the tray drive unit
on end. Remove the shaft
side plate and remove the tray drive unit.
Note: After removal, remove 2 gears
Figure 3-315
1
and stand it
2
from the
3
.
CANON DR-X10C FIRST EDITION