CHAPTER 2 FUNCTION & OPERATION
The power supply PCB contains a fuse,
and if an excessive current flows, the fuse
blows and the power supply stops. The motor
driver has a protection function and if an ex-
cessive current flows, the power supply to the
motor stops.
This machine will shift into the stand-by
mode (Energy Star mode) if no key or no scan
operation takes place after the power is turned
ON. Select shifting time from 240/60/10 min-
utes according to the "Stand-by Mode Setting"
in the user mode. It is set to "10 minutes" at the
factory.
If communication is performed from a
computer or a key on the operation panel is
pressed, the machine resumes from the
stand-by mode.
This machine conforms to the standards
defined by the International Energy Star Pro-
gram.