Second Edition • Second Printing
Electrocution Hazards
This machine is not electrically insulated and will
not provide protection from contact with or
proximity to electrical current.
Obey all local and governmental regulations
regarding required clearance from electrical power
lines. At a minimum, the required clearance
contained in the chart below must be followed.
Line Voltage
0 to 50KV
50 to 200KV
200 to 350KV
350 to 500KV
500 to 750KV
750 to 1000KV
Allow for platform movement, electrical line sway or
sag and beware of strong or gusty winds.
Keep away from the machine if it contacts
energized power lines. Personnel on the ground or
in the platform must not touch or operate the
machine until energized power lines are shut off.
Part No. T107112
Required Clearance
3.0 m
4.6 m
6.1 m
7.6 m
10.6 m
13.7 m
S-60 HC
Do not operate the machine during lightning or
storms.
Do not use the machine as a ground for welding.
Tip-over Hazards
Occupants, equipment and materials shall not
exceed the maximum platform capacity for the
restricted or unrestricted range of motion.
Maximum platform capacity
Unrestricted range of motion
Restricted range of motion
Maximum occupants
S-60 HC: Do not attach a platform rated at 340 kg
(unrestricted range of motion) and 567 kg (restricted
range of motion) to machines with any other rated
load. See the serial label for the maximum rated
load.
The weight of options and accessories, such as
pipe cradles, panel cradles and welders, will reduce
the rated platform capacity and must be factored
into the total platform load. See the decals with the
options and accessories.
If using accessories, read, understand and obey
the decals and instructions with the accessory.
Operator's Manual

Work Area Safety

340 kg
567 kg
3
9