Second Edition • Second Printing
Test Emergency Controls
12 Turn the key switch to ground control and shut
the engine off.
13 Pull out the red Emergency Stop button to the
on position.
14 Simultaneously hold the
emergency power switch on and
activate each boom function
toggle switch.
Note: To conserve battery power, test each
function through a partial cycle.
Result: All boom functions should operate.
At the Platform Controls
Test Emergency Stop
15 Turn the key switch to platform control and
restart the engine.
16 Push in the platform red Emergency Stop button
to the off position.
Result: The engine should turn off and all
functions should not operate.
17 Pull out the red Emergency Stop button and
restart the engine.
Test the Horn
18 Push the horn button.
Result: The horn should sound.
Part No. T107112
Test the Foot Switch
19 Push in the platform red Emergency Stop button
to the off position.
20 Pull out the red Emergency Stop button to
the on position but do not start the engine.
21 Press down the foot switch and attempt to start
the engine by moving the start toggle switch to
either side.
Result: The engine should not start.
22 Do not press down the foot switch and restart
the engine.
23 Do not press down the foot switch. Test each
machine function.
Result: The machine functions should not
operate.
Test Machine Functions
24 Press down the foot switch.
25 Activate each machine function control handle
or toggle switch.
Result: All boom/platform functions should
operate through a full cycle.