Inspections
1 Select a test area that is firm, level and free of
obstruction.
At the Ground Controls
2 Turn the key switch to ground control.
3 Pull out the red Emergency Stop button to
the on position.
Result: The beacon (if equipped) should flash.
4 Start the engine (see Operating Instructions
section).
Test Emergency Stop
5 Push in the red Emergency Stop button to the
off position.
Result: The engine should turn off and all
functions should not operate.
6 Pull out the red Emergency Stop button to
the on position and restart the engine.
Test the Machine Functions
7 Do not push the function
enable button. Attempt to
activate each boom and
platform function toggle
switch.
Result: All boom and platform functions should
not operate.
28
8 Push and hold the function enable button and
activate each boom and platform function toggle
switch.
Result: All boom and platform functions should
operate through a full cycle. The descent alarm
should sound while the boom is lowering.
Test the Tilt Sensor
9 Pull out the platform red Emergency Stop button
to the on position. Turn the key switch to
platform control.
10 Open the tank side turntable
cover and locate the tilt sensor
next to the fuel tank.
11 Press down one side of the tilt
sensor.
Result: The alarm, located in the
platform, should sound.