Work Area Safety

Electrocution Hazards
This machine is not electrically insulated and will
not provide protection from contact with or
proximity to electrical current.
Line Voltage
0 to 50KV
50 to 200KV
200 to 350KV
350 to 500KV
500 to 750KV
750 to 1000KV
Allow for platform movement, electrical line sway
or sag, and beware of strong or gusty winds.
Do not operate the machine during lightning or
storms.
Do not use the machine as a ground for welding.
Part No. 133564
Obey all local and
governmental
regulations regarding
required clearance from
electrical power lines. At
a minimum, the required
clearance contained in
the chart below must be
followed.
Required Clearance
10 ft
3.05 m
15 ft
4.60 m
20 ft
6.10 m
25 ft
7.62 m
35 ft
10.67 m
45 ft
13.72 m
Keep away from the
machine if it contacts
energized power lines.
Personnel on the ground
or in the platform must
not touch or operate the
machine until energized
power lines are shut off.
GS-3384 • GS-3390• GS-4390• GS-5390
Work Area Safety
Tip-over Hazards
Occupants, equipment and materials shall not
exceed the maximum platform capacity or the
maximum platform capacity of the platform
extension.
Maximum capacity – GS-3384 and GS-3390
Maximum occupants
Models with one platform extension
Platform
retracted
Platform only
Extension only
Extension only
500 lbs / 227 kg
Models with two platform extensions
Platform retracted
Platform with one
extension out
Platform with two
extensions out
Each extension
only
Extension only
Platform only
500 lbs / 227 kg
1500 lbs /
680 kg
Operator's Manual
2500 lbs
1134 kg
2000 lbs
907 kg
500 lbs
227 kg
Platform only
2000 lbs / 907 kg
2500 lbs
1134 kg
2000 lbs
907 kg
1500 lbs
680 kg
500 lbs
227 kg
Extension only
500 lbs / 227 kg
7