4.9 Control and Feedback Interfaces in Standard Mode

4.9
Control and Feedback Interfaces in Standard Mode
Note
For the 1SSI, the following data of the control and feedback interface are consistent:
Byte 0 to 3
Byte 4 to 7
Use the access or addressing mode for data consistency over the entire control and
feedback interface on your master (only for configuration using the GSD file).
Description
The two tables show the assignment of the control interface (outputs) and the feedback
interface (inputs):
Table 4-3
Assignment of the Feedback Interface (Inputs)
Address
Bytes 0 to 3
Byte 4
Byte 5
Bytes 6 to 7
244
Assignment
Encoder value double word (bit 31 set, encoder value frozen)
0 or sign of life LZ
Bit 6: Ready for operation RDY
Bit 5: Parameter assignment error ERR_PARA
Bit 4: Absolute encoder error ERR_SSI
Bit 3: Encoder supply short circuit ERR_24V
Bit 2: Status DI STS_DI
Bit 1: Status DN STS_DN
Bit 0: Status UP STS_UP
Bit 7: Reserved = 0
Bit 6: Reserved = 0
Bit 5: Reserved = 0
Bit 4: Reserved = 0
Bit 3: Comparison value 2 reached, CMP2
Bit 2: Comparison value 1 reached, CMP
Bit 1: Load function error, ERR_LOAD
Bit 0: Load function running, STS_LOAD
Reserved = 0
Technological Functions
Operating Instructions, 02/2007, A5E00124867-05