Upgrading Firmware; Tel. 07131 911201 Fax 07131 911203; Managing Receptacles - Extron electronics IPL T PCS4 User Manual

Ip link power control interface
Hide thumbs Also See for IPL T PCS4:
Table of Contents

Advertisement

im Vertrieb von
Web Page-Based Setup and Control, cont'd
8.
9.

Upgrading firmware

The Firmware Upgrade screen lets you browse to locate and upload a new
version of firmware for your unit. The uploaded file must have the file extension
.S19.
Firmware upgrade screen
To upload a new version of firmware:
1.
2.
3.
4.

Managing receptacles

On the Switching/Grouping screen, you can switch power on and off to each
individual receptacle, group the receptacles together, and power each group on
and off. You can also view the threshold settings (Full, Standby, None, or Not Set)
indicating the device power level at which the alarm relay will be activated for
each receptacle.
www.camboard.de
4-14
IPL T PCS4 • Web Page-Based Setup and Control
CAMBOARD Electronics
Click the Save button beside the file name that you entered. The e-mail alert
information is saved on the PCS4, and the Save button becomes Edit again.
Repeat steps 5 through 8 for each e-mail recipient address that you want to
add or edit.
The PCS4's .S19 file is not the same as the .S19 files of other products and
is not interchangeable with any other product's firmware upgrade files.
On the side-bar menu of the Configuration tab, click Firmware Upgrade.
The Firmware Upgrade screen is displayed, showing the version of
firmware that is currently loaded.
Click Browse to open a Windows file selection window.
On the file selection window, locate the new firmware version file on your
server and double-click it. (Firmware files must have the extension .S19.)
The firmware file name and path are displayed in the Current Firmware
Version field on the Firmware Upgrade screen.
Click Upload. When the firmware upgrade is complete, the Power LED on
the unit blinks three times.
If you attempt to upload a file with an extension other than .S19, the PCS4
recognizes it as invalid and ignores it, reverting to the factory installed
firmware version.
You cannot set the reference thresholds on this screen. This can be done only
from the IPL T PCS4 front panel or via SIS commands. Refer to Setting
power level reference thresholds in chapter 3 or to chapter 5, SIS
Programming and Control, for information on setting thresholds from the
front panel or via SIS commands.
Tel. 07131 911201
Fax 07131 911203
ce-info@camboard.de

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ipl t pcs4i

Table of Contents