Front Panel Features and Operation, cont'd
The Full and Standby reference thresholds must be configured with the device
attached to the PCS4 receptacle. The thresholds must be set in the correct order,
with Full being set first. Follow these steps to set the threshold for each device,
using the front panel. (These thresholds also can be configured using the Web
pages or SIS commands. Refer to chapters 4 and 5, respectively.)
1.
2.
To set the Full power threshold:
3.
4.
5.
6.
To set the Standby power threshold:
7.
8.
www.camboard.de
3-4
IPL T PCS4 • Front Panel Features and Operation
CAMBOARD Electronics
The Full threshold must be set first. If Standby is set first, the Standby
reference setting is removed by the setting of the Full reference threshold.
Connect a device to a power output receptacle on the IPL T PCS4. Make a
note of the receptacle number to which you connected it (1-4).
Press the corresponding front panel button to activate the receptacle. Check
to ensure that the receptacle's red Power LED is lit.
Power on the attached device.
Press and hold the Full button on the PCS4 front panel.
SET REFERENCE
FULL
STANDBY
While holding the Full button, press and release the button for the
receptacle into which the device is plugged. Both the green F (Full) LED
and the yellow S (Standby) LED for the selected receptacle blink twice.
Only the green Full LED remains lit.
1
Green
F
Full
LED
S
Receptacle
Button
Release the Full button. The Full threshold for the receptacle is now set.
Power off the attached device.
Press and hold the Standby button.