Extron electronics IPL T PCS4 User Manual page 56

Ip link power control interface
Hide thumbs Also See for IPL T PCS4:
Table of Contents

Advertisement

im Vertrieb von
SIS
Programming and Control, cont'd
X67
= Threshold settings for all ports
0 = None
1 = Full
2 = both (Full and Standby thresholds)
=
(Ethernet only) Number of seconds before
X69
timeout on IP connections (min = 1,
max = 6500, and default = 30 = 300 seconds).
If no data is received during the timeout
period, the Ethernet connection is closed.
Each step is 10 seconds. The response is
returned with leading zeros.
= The number (as an optional parameter) that is
X70
inserted into the e-mail message if the .eml
file has an embedded
(with no parameters).
= Condition that is monitored
X701
0 = Receptacle off
1 = Receptacle on
2 = Reference: None
3 = Reference: Standby
4 = Reference: Full
5 = Any change
= Use alarm relay
X702
0 = no/disable
1 = yes/enable
= E-mail to use 61-64
X703
= Enable/disable monitoring
X704
0 = disable monitoring
1 = enable monitoring
2 = enable with e-mail
= Alarm status
X705
0 = inactive
1 = active
2 = silenced
X706
= Clear value
0 = condition no longer met
1 = clear with output off
2 = clear with output on
3 = clear with no threshold
4 = clear with standby threshold
5 = clear with full threshold
6 = clear with any change
7 = manual
= Relay polarity
X707
0 = normally open
1 = normally closed
= Time to hold alarm active before canceling
X708
0 = never times out
1-7 = 1 to 7 minutes
= On timed value
X709
0-15 (in 250 ms)
= Off timed value
X710
0-15 (in 250 ms)
= Day of the week
X711
1 = Sunday
2 = Monday
3 = Tuesday
4 = Wednesday
5 = Thursday
6 = Friday
7 = Saturday
= Time in minutes (0-1440)
X712
0 = 00:00 a.m. (midnight)
www.camboard.de
5-6
IPL T PCS4 • SIS
CAMBOARD Electronics
command
Esc
Tel. 07131 911201
Programming and Control
Fax 07131 911203
1440 = clear schedule
Example: 1439 = 11:59
Use the following formula (in 24-hour time
format):
(Hour * 60) + minutes = time in minutes
ce-info@camboard.de