Table 3-12     Problems resolved in XCP 2210 (continued)
SPARC M10-
RTI No.
1
4
4S
RTIF2-
x
x
x
140605-005

Problems resolved in XCP 2092

The following table lists the problems resolved in XCP 2092.
Fujitsu M10/SPARC M10 Systems Product Notes for XCP Version 2240 ・ March 2015
114
Description
If either of the following events occurs,
the ttydm process may fail, causing the
XSCF to be reset:
- The console(8) command is executed to
connect to the control domain console
after one of the following events
occurs: A large amount of data is
output to the screen of the domain
console and the console(8) command
terminates when the XSCFs for
multiple SPARC M10-4S chassis are
reset.
- The console(8) command is executed to
forcibly connect to the control domain
console.
If the ttydm process fails, the following
error log is registered:
[Example]
XSCF> showlogs error -v
Date: Dec 01 22:08:13 JST 2013
Code: 20000000-00fcff00b0000000ff-
010400010000000000000000
Status: Notice Occurred: Dec 01
22:08:04.886 JST 2013
FRU: /FIRMWARE,/XBBOX#80/XSCFU
Msg: SCF process down detected
Diagnostic Code:
00000000 00000000 0000
50000000 00000000 0000
00000000 00000000 0000
74747964 6d2e3239 37302e62 7a320000
00000000 00000000 0000
If the first five bytes on the fourth line in
[Diagnostic Code:] are "747479646d", the
ttydm process has failed.
Workaround
There is no effective workaround.
[How to restore]
- In the case of a system that consists of
multiple SPARC M10-4S chassis
By executing the console(8) command
after XSCF resetting, which causes
master/standby XSCF switching, you
can connect to the control domain
console.
- In the case of SPARC M10-1, SPARC
M10-4, or SPARC M10-4S in a
single-chassis configuration
By executing the console(8) command
after XSCF resetting, you can connect to
the control domain console.