Table 3-15     Problems resolved in XCP 2090 (continued)
SPARC M10-
RTI No.
1
4
4S
RTIF2-
x
x
x
131213-017
RTIF2-
x
x
x
131213-018
RTIF2-
x
x
x
131213-020
Description
Any of the following may occur while
XSCF is running.
[Symptom1]
Process down occurs and XSCF resets.
[Symptom2]
Response of commands which deals
with acquiring MIB information (get
command, etc.) becomes slow.
[Symptom3]
Execution of commands like
showhardconf(8) takes time. Moreover,
when the showhardconf(8) command is
executed, the following message may be
output and the command is terminated
abnormally.
"Cannot communicate with the other
XSCF. Check the other XSCF' stat"
[Symptom 4]
The "SCF panic detected" error is
produced and the XSCF is reset.
[Symptom 5]
Login to XSCF Web fails. However, login
to the XSCF shell is possible.
If XSCF has disabled the setup of NTP
client, the time difference between XSCF
and the hypervisor of each physical
partition (PPAR) is mistakenly updated
and the time of the logical domain may
be misaligned after PPAR is rebooted.
Due to the retry functionality of XSCF, if
any abnormality occurs in the recoverable
backup memory inside the PSU
backplane (PSUBP) for more than three
times, XSCF regards it wrongly as a fixed
error and the starting of XSCF may be
deterred.
In such a case, the "REBOOT: COUNTER
ERROR" message is displayed.
Workaround
There is no effective workaround.
[How to restore]
- For symptoms 1, 2, and 4:
The system can be recovered by
resetting XSCF. The system can be
used after that.
- For symptom 3 and 5:
Reset XSCF with the rebootxscf(8)
command.
Enable the NTP client setup of XSCF by
executing the "setntp -s client -c enable"
command and synchronize XSCF with
the upper level NTP server. Otherwise,
execute the following.
1. Execute the showdateoffset(8)
command before powering on or
rebooting the PPAR and confirm the
time difference between XSCF and the
hypervisor.
2. If the time difference is too large,
execute the resetdateoffset(8) command
with the PPAR at stopped state, in
order to reset the time difference.
3. After powering on the PPAR, reset the
time of Solaris OS.
There is no effective workaround.
[How to restore]
Re-execute power off and on.