Table 3-5 Problems that might occur with XCP 2240 and workarounds (continued)
SPARC M10-
RTI No.
1
4
4S
Workaround for RTIF2-140304-007
If PSU is replaced by the replacefru(8) command, after mounting the new PSU, wait
for at least 30 seconds before pressing the [f] key of the menu of replacefru(8) command.
Do you want to continue?[r:replace|c:cancel] : r
Please execute the following steps:
1) Remove PSU#n.
2) Execute either the following:
2-1) After installing the exchanged device, please select 'finish'.
2-2) If you want to suspend the maintenance without exchanging device,
please select 'cancel'.
[f:finish|c:cancel] : f
[How to restore]
If both PSUs become "Deconfigured" without performing workarounds, active
replacement of the PSUs cannot be done with the replacefru(8) command.
Maintenance/Replacement Menu
Please select a FRU to be replaced.
No. FRU Status
--- ------------------- --------------
1 /PSU#0 Deconfigured
2 /PSU#1 Deconfigured
------------------------------------------------------------------------------
Select [1,2|b:back] : 2
[Warning:307]
PSU#1 cannot be replaced. Please verify the configuration.
Select [1,2|b:back] : 2
[Warning:307]
Fujitsu M10/SPARC M10 Systems Product Notes for XCP Version 2240 ・ March 2015
82
Description
partition is active (the status is other
than "Powered Off").
- You can access XSCF, but the execution
result of the showlogs power command
does not include "SCF Reset" indicating
that XSCF is reset.
*1: If a power failure notification is
issued, usually the following log is
registered by the showlogs event
command.
PSU input power failure(/PSU#0)
PSU input power failure(/PSU#1)
In addition, the following error log is
detected in many cases when the trouble
in [1] occurs:
failed to read/write extended active
status register
Workaround