Table 3-5     Problems that might occur with XCP 2240 and workarounds (continued)
SPARC M10-
RTI No.
1
4
4S
RTIF2-
x
x
x
140804-002
RTIF2-
x
140808-002
RTIF2-
x
x
x
140808-003
RTIF2-
x
x
x
140929-001
RTIF2-
x
x
x
140929-002
RTIF2-
x
x
x
141008-001
Fujitsu M10/SPARC M10 Systems Product Notes for XCP Version 2240 ・ March 2015
76
Description
Although the showstatus(8) command is
executed when there are no faulty
components, the message "No failures
found in System Initialization."
indicating that there is no faulty
component does not appear.
[Example]
XSCF> showstatus
XSCF>
When the showhardconf(8) command is
executed after the input power is turned
off and then on, information on the
configuration of components installed on
the system may not be recognized.
After the occurrence of a component
failure, you may fail to power off the
physical partition (PPAR).
This phenomenon may occur when the
following procedure is performed:
1. While the PPAR is being reactivated
due to a component failure, the
poweroff(8) command is executed
without the -f option.
2. After the PPAR is powered off upon a
PPAR reactivation failure due to a
component failure, the poweron(8)
command is executed to power on the
PPAR.
3. The poweroff(8) command is executed
without the -f option.
"NOTICE: Unable to get TX queue state!"
is displayed mistakenly if Oracle Solaris
is started in the system configured with
Oracle Solaris kernel zones.
The setting of the power supply
interlocking function (RCIL) disappears
if a microSD card, which is mounted on a
mother board unit (MBU) or a CPU
memory unit lower (CMUL), is replaced
in the system with a single unit
configuration of SPARC M10-1, SPARC
M10-4 or SPARC M10-4S.
The setsnmp(8), setsnmpusm(8), or
setsnmpvacm(8) command may fail to
reflect settings properly if the settings are
changed to valid immediately after being
Workaround
There is no effective workaround.
If no message appears, there are no faulty
components. You can continue system
operation.
There is no effective workaround.
[How to restore]
Execute the rebootxscf -a command to
reset all XSCFs.
Do not execute the poweroff(8) command
while the PPAR is being reactivated due
to a component failure.
[How to restore]
Execute the shutdown command from
Oracle Solaris to power off the PPAR.
[Example]
# shutdown -y -g0 -i5
There is no effective workaround.
Ignore this message.
There is no effective workaround.
[How to restore]
See the Fujitsu M10/SPARC M10 Systems
RCIL User Guide, and reconfigure RCIL.
Be sure to wait 30 seconds or more if the
settings are changed to valid after being
changed to invalid.
[How to restore]