Fujitsu M10 Product Notes page 84

Hide thumbs Also See for M10:
Table of Contents

Advertisement

Table 3-5     Problems that might occur with XCP 2240 and workarounds (continued)
SPARC M10-
RTI No.
1
4
4S
RTIF2-
x
x
x
140602-001
RTIF2-
x
140605-001
Fujitsu M10/SPARC M10 Systems Product Notes for XCP Version 2240 ・ March 2015
70
Description
of "#"s as the result of the showhardconf
(8) command.
[Example]
When the crossbar cable is loose:
+ FRU-Part-Number:################;
Ver:####h;
+ Type:#######; Length: #;
When the input power of a PCI
expansion unit is turned off (AC OFF), an
error log is registered but, notification
through SNMP trap or REMCS is not
performed. Confirmation that the input
power of a PCI expansion unit had been
turned off can be seen in the output of
the "showlogs error" command, like the
following:
Date: May 29 20:03:05 JST 2014
Code: 10000400-00d4000000ff0000ff-
1100002a0000000000000000
Status: Information
Occurred: May 29 20:03:00.905 JST 2014
FRU: /BB#0/PCI#8/PCIBOX#2003/
PSU#0
Msg: AC FAIL
Diagnostic Code:
00083230 30330000 0000
00080000 00000000 0000
00080000 00000000 0000
00000000 00000000 00000000
00000000
00000000 00000000 0000
Suppose the following scenario: You turn
on the power to a physical partition
(PPAR) that consists of multiple SPARC
M10-4S chassis. The status of the
PPAR/domain is between self diagnosis
test (POST) completion (Initialization
Complete) and OpenBoot PROM start
completion (OpenBoot Running). If the
Workaround
(PPAR) by the poweroff(8) command.
2. Check the physical state of the crossbar
cable (loose connection, disconnection
etc.) who component information is
depicted by a number of "#"s.
3. Execute the poweron(8) command to
power on the PPAR.
4. Check the component information of
the target crossbar cable with the
showhardconf(8) command.
[Example] When the crossbar cable is
properly connected:
+ FRU-Part-Number:2123628-2 ;
Ver:3920h;
+ Type:Optic; Length: 2;
There is no effective workaround.
There is no effective workaround.
[How to restore]
Perform one of the following operations:
- Execute the rebootxscf -a command.
- From XSCF Web, reset all XSCFs.
- Turn off the power to the PPAR, and
then turn it on again.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sparc m10

Table of Contents