Table 3-5     Problems that might occur with XCP 2240 and workarounds (continued)
SPARC M10-
RTI No.
1
4
4S
RTIF2-
x
x
x
150126-001
Fujitsu M10/SPARC M10 Systems Product Notes for XCP Version 2240 ・ March 2015
80
Description
may not start. If ntpd is not active, a
message "NTP is unavailable." is output
by executing the showntp -l command.
Note that this problem does not occur if
the NTP client setting of XSCF and the
NTP server setting are disabled.
If XSCF is reset while the system is
operating with the power supply
interlocking function enabled, the power
of an external I/O device may be turned
off incorrectly.
Workaround
is enabled, execute the rebootxscf(8)
command to reset XSCF.
Disable the power supply interlocking
function by RCIL, and enable it again
every time after the power of the physical
partition (PPAR) is turned on.
This also applies when the power of the
PPAR is automatically turned on due to
power failure, power recovery, auto
power control system (APCS), RCIL, etc.
[Example]
XSCF> setremotepwrmgmt -c disable
XSCF> setremotepwrmgmt -c enable
Perform the following procedure when
you cannot perform this workaround
due to a system operation issue.
- When two or more SPARC M10
systems are registered to the power
supply interlocking group
Do no reset XSCF at the same time as
XSCF resetting of other SPARC M10
system.
- When only a single SPARC M10 system
is registered to the power supply
interlocking group
Perform either (1) or (2) below.
(1) Disable only the power-off of the
power supply interlocking function.
1. Execute "setremotepwrmgmt -c
disable" to disable the power
supply interlocking.
2. Specify "0x01" for the Linkage
value in the management file of
the power supply interlocking.
[Example]
1,1,0x01,
00000000000000000000000000000011,
0x01,0x00,,,10.20.300.40,0x20,aa:bb:cc:dd:
ee:f0,,,,,,,,,,
1,2,0x10,
00000000000000000000000000000022,
0x01,0x00,,,10.20.300.41,0x20,aa:bb:cc:dd:
ee:f1,,,,,,,,,,
3. Execute "setremotepwrmgmt -c
config [file name]" to apply the
management file.