Table 3-17     Problems resolved in XCP 2070 (continued)
SPARC M10-
RTI No.
1
4
4S
RTIF2-
x
130711-001
RTIF2-
x
x
x
130716-001
RTIF2-
x
130801-001
RTIF2-
x
x
x
130802-001
Fujitsu M10/SPARC M10 Systems Product Notes for XCP Version 2240 ・ March 2015
130
Description
When you perform maintenance of the
SPARC M10-4S by executing the
replacefru(8) or addfru(8) command, the
"FMEM serious error" error log may be
registered and the replacefru(8) or
addfru(8) command may fail.
Also, when you turn on the power to the
physical partition (PPAR) during the
execution of the flashupdate(8)
command, similarly, the "FMEM serious
error" error log may be registered and the
flashupdate(8) command may fail.
When you update the PCI expansion unit
firmware by executing the ioxadm(8)
command, a "LINKCARD I2C error"
error may occur.
Even if you execute the switchscf(8)
command, the XSCF may not be
switched. At this time, the master XSCF
and standby XSCF cannot communicate
with each other, and the redundancy of
the XSCF is not maintained.
When you specify USB memory for the
getflashimage(8) command, the
following message may be output and
the execution of the command may fail.
Error: Unable to mount USB device.
Workaround
For details, see
"Response to "FMEM
serious error" of SPARC M10-4S
(RTIF2-130711-001)."
There is no effective workaround.
However, if both of the conditions below
can be confirmed, the update of the PCI
expansion unit firmware has been
completed normally. In this case, ignore
the "LINKCARD I2C error" error
message, and continue the operation.
- The update of the PCI expansion unit
firmware by using the ioxadm(8)
command has been completed normally.
- Executing the ioxadm -v list command
displays the version number of the PCI
expansion unit firmware that has been
specified for the update.
There is no effective workaround.
If the XSCF is not switched even by
executing the switchscf(8) command,
execute the replacefru(8) command to
perform active replacement of the XSCF
unit that is in the standby chassis. Also,
when you disconnect the XSCF unit,
disconnect and then connect the XSCF BB
control cable.
After disconnecting and then connecting
the USB memory, execute the
getflashimage(8) command again.