Table 3-17     Problems resolved in XCP 2070
SPARC M10-
RTI No.
1
4
4S
RTIF2-
x
x
x
130228-001
RTIF2-
x
x
x
130516-001
RTIF2-
x
130709-001
Description
If a physical partition (PPAR) is powered
on again after the PPAR is forcefully
powered off with the poweroff -f
command while starting up Oracle
Solaris, "Unable to connect to Domain
Service providers" is output to the OS
console and Oracle Solaris may not be
started.
In a system configuration for which
power supply interlocking with
ETERNUS is set, ETERNUS is not
powered on even if the power is turned
on from the power switch located on the
operation panel of the SRARC M10
system.
In the state where the physical partition
(PPAR) is powered on, when switching
of the master XSCF occurs, it may take
time before the standby XSCF switches to
the master XSCF. As a result, the
following error may occur.
Master switch synchronization timeout
Workaround
Power on the PPAR again with the
poweron(8) command after disconnecting
the power of the PPAR with the
poweroff(8) command. If Oracle Solaris
does not start up even after that, reset the
XSCF after disconnecting the power of
the PPAR and then power on the PPAR
again.
Turn on the power in one of the
following ways:
- XSCF command, poweron(8) command
- Menu on the XSCF Webpage
- Automatic power turning on with
schedule settings
There is no effective workaround.
[How to restore]
- If the error occurs during execution of
the flashupdate(8) command when the
power to the PPAR is on:
Turn off the power to the PPAR, and
then execute the flashupdate(8)
command again.
- If the error occurs during execution of
the switchscf(8) command when the
power to the PPAR is on, or if the error
occurs due to an XSCF failure (process
down etc.) when the power to the
PPAR is on:
Perform recovery of the SPARC
M10-4S chassis for which the "XSCF
hang-up is detected" error log has been
registered by using either of the
following methods.
- Execute the replacefru(8) command
to replace the CPU memory unit
lower (CMUL) or XSCF unit (XSCFU).
- Power off and on the CPU memory
unit lower (CMUL) or the XSCF unit
(XSCFU).
Chapter 3 Information on Software
129