Table 3-5     Problems that might occur with XCP 2240 and workarounds (continued)
SPARC M10-
RTI No.
1
4
4S
RTIF2-
x
x
x
141031-002
RTIF2-
x
x
x
141111-001
Description
changed to invalid.
[Example] The command fails, and some
of the settings (Enabled MIB Modules)
are not reflected properly:
XSCF> setsnmp disable
XSCF> setsnmp enable
setsnmp: Agent enable failed
XSCF> showsnmp
Agent Status: Enabled
Agent Port: 161
System Location: System-Location
System Contact: System-Contact
Status: Enabled
Community String: public
Enabled MIB Modules: None <-- not
reflected
XSCF>
"SP MIB" is displayed in "Enabled MIB
Modules" when the settings are reflected
properly.
Expiration date for the self-authenticated
certificate used by the HTTPS service will
arrive in 1 year, not in 10 years.
On SPARC M10-1/M10-4 or SPARC
M10-4S in a single-chassis configuration,
the content of the scheduled operation
setting for automatic power-on/power-
off is lost and automatic power-on/
power-off becomes disabled. It occurs
even when the PSU backplane (PSUBP)
and the microSD card, or the PSU
backplane unit (PSUBPU) and the
microSD card are not replaced at the
same time as shown in the following
procedure.
1. Turn off the input power (AC OFF)
and replace PSUBP or PSUBPU.
2. Turn on the input power (AC ON) and
start XSCF.
3. Turn off the input power (AC OFF)
and replace the microSD card on the
mother board unit (MBU) or CPU
memory unit lower (CMUL).
Workaround
Execute the command again after a lapse
of 30 seconds or more.
After executing the command again,
confirm the settings are reflected as
expected executing the showsnmp(8),
showsnmpusm(8), or showsnmpvacm(8)
command.
You can access to XSCF Web even
though the certificate has expired. Use
the same certificate, or create a certificate,
or import a certificate with the sethttps(8)
command.
To take over the content of the scheduled
operation setting from the replaced FRU,
disable/enable the scheduled operation
after the first FRU is replaced. Execute
the following procedure.
1. Replace the first FRU. (step 1 in the
Description)
2. Disable the scheduled operation.
XSCF> setpowerschedule -a -c
control=disable
3. Enable the scheduled operation again.
XSCF> setpowerschedule -a -c
control=enable
4. Execute step 2 and the subsequent
steps in the Description.
[How to restore]
- If the dumpconfig(8) command is used
to save the XSCF setting information,
execute the restoreconfig(8) command
and restore the XSCF setting
Chapter 3 Information on Software
77