Operating Instructions; Introduction; Test Selection - HP Series 37 Reference Manual

3000 series self test and maintenance mode
Table of Contents

Advertisement

OPERA TING INSTRUCTIONS
I~
~
__________________________________________
~II
I
2.0 INTRODUCTION
This section of the manual describes how to operate the PICDIAG.
The primary function of the PICDIAG is to test and diagnose the HP 3000 Series 37 Peripheral Interface
Card. The PICDIAG will isolate faults to the component level wherever possible.
You control test selection, looping, error handling, and printing messages.
2.1 TEST SELECTION
The PICDlAG is divided into tests that can be run individually or in various combinations.
Use the
STATE
command to list which tests and commands are currently selected. When the PICDIAG is
in the default configuration, the
STATE
command will display the following message:
PICDIAG STATUS:
PATH:
X
X
CHANNEL:
X
X
EEPR:
ON
EEPS:
ON
ENPR:
ON
LOOP:
OFF
PRINT:
OFF
TRACE:
OFF
Sections Selected:
1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,16,17,18,19,20,21,22,
23,25,28,29,30,32,33,34,35,36,37,39,41,42,43,44,45
To change the test selection, type
TEST,
then use a '-' in front of the test number(s) to be deleted, a '+' in
front of the test number(s) to be added, or simply the test number(s) to be executed.
EXAMPLE:
TEST - 3,6 deletes test sections 3 and 6
TEST + 1,5,6 adds test sections I, 5, and 6
TEST 1/5,8 executes test sections 1-5, and 8
Test 41 through 45 require a second PIC.