3000 series self test and maintenance mode
Table of Contents

Advertisement

Operating Instructions
8) The memory diagnostic ioads and executes Test Section
1.
The ronowing message is then dispiayed:
HP 3000 Series 37 Memory Diagnostic - (MDIAG37 nn.nn XX/XX/XX)
Begin Section 1
Begin Step 11
If step 11 terminates with an error then there are fatal
multiple-bit errors in low memory and the diagnostic will fail
to run properly.
Step 11 completed
Begin Step 12
Step 12 completed
Begin Step 13
Detected X banks of memory on X boards using 64K RAMS
Step 13 completed
Begin Step 14
Step 14 completed
End of Section 1
Type 'GO' to Continue (HELP to list commands)
9)
At this point,
GO
will execute the default tests (all tests) after Section
1.
To change the test
selection, enter
TEST
with a "_" in front of the test numbers to delete those tests, or a
"+"
in front of
the test numbers to add those tests. Without a "-" or a
"+"
MDIAG37 will perform just those test
sections listed.
Examples:
TEST -5,6,7
or
TEST -5/7
will delete tests 5-7
TES·j +2,3,4
or
TEST +2/4
will add tests 2-4
TEST 1,2,3,6,9
to run tests 1,2,3,6, and
9
(go/no go)
If you inadvertently select no tests by deleting test sections, MDIAG 3 7 will select all tests (default).
10)
Unless the End of Program Pause has been enabled, control is returned to DUS when the diagnostic
has been executed.
SEP 84