Operating Instructions
2.6 HOW TO CONFIGURE MDIAG37
You can configure and reconfigure the diagnostic according to your needs.
MDIAG performs initialization and Section I, followed by a prompt for an operator command. If you are
going to use the default commands (indicated with an asterisk in Table 2-1), type
GO
in response to the
prompt. If you want to reconfigure the diagnostic, you can do so at this point or after you interrupt the
diagnostic. Table 2 - 1 provides the a vaila ble commands.
COMMAND
EEOPP*
EEPS*
ENDP*
EXIT
GO
HELP
LDS
LOOPTST(n)
LOOPERR
SEP 84
2-4
I
Table 2-1. DIAGNOSTIC COMMANDS
NAME
DESCRIPTION
Enable End Of Program Pause
allows end of program pause
Enable Error Pause
halts after error occurs
Enable Non-error Display
allows information messages
I
Exits the diagnostic
returns to DUS
resumes program at current step
I
allows diagnostic to continue at
current step
lists commands
I
lists available commands with a brief
description
I
List Diagnostic Status
I
Lists the following information:
I
which test sections are enabled
ENDP flag: true or false
EEPS flag: true or false
EEOPP flag: true or false
LOOPTST flag: true or false
LOOPERR flag: true or false
PEMP flag: true or false
number of executed diagnostic passes
Loop on current Test list
May enter a repetition factor. If a
parameter is blank, the loop continues
until LOOPOFF is set.
Loop on test with Error
Loops on failed test section. Halt
i
LOOPERR with CNTRL-Y
I
LOOPERR is not available in test
I
sections I, 8, and 9.
I
I