28
Insulated Chimney – Installation and System Height
Minimum 15' system
height (measured
from the base of the
fireplace)
Maximum 35' system
height (measured
from the base of the
fireplace)
MINIMUM HEIGHT
WITH OFFSETS
One Pair (2) Offsets
Mininum system
height is 17'.
Two Pairs (4) Offsets
Minimum chimney
height is 19'.
NOTE: In problematic
locations (areas with
high wind or at altitude,
etc.) additional chimney
height above the
specified minimum may
be necessary to reduce
wind-induced down
drafts, back puffing, or
smoke spillage. By
adding additional
chimney, the fireplace
will have increased draft
and encounter less
negative operating
characteristics.
© Travis Industries
Installation
(for qualified installers only)
Follow the chimney
manufacturer's instructions
for clearances and framing
dimensions.
Follow the chimney
manufacturer's instructions
for clearances and framing
dimensions.
Maximum
System Height
35' Max. (10.5M)
15' Min. (4.5M)
8/24/2017 - 1450
Storm Collar
Flashing
Maximum 8' Chimney Section
(4' if two pairs of 30° elbows
used)
30°
Cap (see "Chimney
Termination Requirements")
Do not seal or caulk the area
between the chimney and flashing.
Attic Firestop (with insulation shield)
Chimney must be totally
enclosed when passing
through living space.
Firestop Required Between
Floor Levels (or fireplace
enclosure)
42 Apex CF