Insulated Chimney Requirements (7" Inner Diameter); Security Asht+ (S2100+) Part Numbers (Available Through Travis Ind.); Security Asht+ - Clearances To Combustibles; Security Asht+- Anchor Plate Installation - FireplaceXtrordinair 42 Apex Clean Face Installation Manual

Wood-burning zero-clearance fireplace
Hide thumbs Also See for 42 Apex Clean Face:
Table of Contents

Advertisement

26

Insulated Chimney Requirements (7" Inner Diameter)

Security ASHT+ (S2100+) Part Numbers (available through Travis Ind.)

Security ASHT+ (S2100+) Chimney Components
7" Internal diameter, 9" outside diameter
VENT, 7" ANCHOR PLATE (REQUIRED) – Includes Instruction Sheet
VENT, 7" 48" CHIMNEY
VENT, 7" 36" CHIMNEY
VENT, 7" 24" CHIMNEY
VENT, 7" 18" CHIMNEY
VENT, 7" 12" CHIMNEY
VENT, 7" 30° OFFSETS (INCLUDES 2 ELBOWS W SUPPORT)
VENT, 7" RAD FIRESTOP
VENT, 7" ATTIC SHIELD
VENT, 7" FLASH 0-6/12
VENT, 7" FLASH 7-12/12
VENT, 7" WALL STRAP
VENT, 7" EXT ROOF BRKT
VENT, 7" STORM COLLAR
VENT, 7" CHIMNEY CAP

Security ASHT+ - Clearances to Combustibles

Maintain a 2" clearance from the chimney to combustibles.
Recommended Space Between Frames = 13-1/4"
Security ASHT+– Anchor Plate Installation
The chimney requires an anchor plate. Attach
the plate to the top of the fireplace with the four
included sheet-metal screws (see illustration to
the right).
Tabs on anchor plate will need to be crimped
before installation.
Seal the fireplace connection with high-
temperature silicone.
Seal the flue liner with furnace cement.
Security ASHT+– Offset Chart
© Travis Industries
Installation
(for qualified installers only)
Space
between
frames
8/24/2017 - 1450
Part #
98900290
98900280
98900281
98900282
98900283
98900284
98900285
98900286
98900287
98900288
98900289
98900292
98900293
98900294
98900295
Firestop
Use high-temperature silicone to
seal the anchor plate.