Chase Ventilation – Front Configuration
If ventilation is provided from the front, you must remove both front inlet knockouts located under the
door opening. The ventilation air passes through the front of the fireplace and exits through the
convection air outlet. In addition, some of this air passes out of the side vents and ventilates the
chase.
When ventilating through the front, the grill is either placed directly on the fireplace or installed into a
raised non-combustible hearth. This hearth must be hollow and able to freely convey air to the
fireplace.
a
NOTE: If supports are provided in front of these knockouts, these supports must not limit the air
opening to less than 50 square inches.
For front configurations, you must use the large grill (38" x 3-3/4" outside dim.), or both small grills
(16-1/4" x 4" outside dim.), or equivalent free air opening (see note above).