10

Fireplace Placement

The fireplace must be secured to the floor and/or framing (see "nailing brackets" in the illustration
below).
Fireplace must be placed directly on wood or non-combustible surface (not on linoleum or carpet).
Fireplace must be installed on a level surface capable of supporting the fireplace and chimney.
Place the ember strip included with the fireplace below the front edge of the fireplace (see illustration
below). This prevents embers from sliding between the fireplace and hearth.
Fireplace must be placed so the vents below and above the glass do not become blocked.
The fireplace must be level and plumb
during installation. Use shims under the
fireplace to properly level the fireplace if
needed.
Fireplace
WARNING:
Failure to correctly level and plumb the
fireplace may lead to the door swinging
open or closed.
© Travis Industries
Installation
(for qualified installers only)
Lifting handles are available separately (98500711).
They attach to the base nailing brackets.
8/24/2017 - 1450
We rcommend the chase around
the fireplace be insulated.
WARNING:
Insulation must be secured so it
does not fill the space between
the fireplace and standoffs.
Standoffs
(on sides and back)
Side Nailing Brackets
(secure to side framing)
Base Nailing Brackets
(bend down and secure to floor)
Center the ember strip below the front edge of the
fireplace and secure it to the floor.