DTX Series CableAnalyzer
Users Manual
Setting
SETUP > Twisted Pair >
HDTDX/HDTDR
SETUP > Twisted Pair >
AC Wire Map
SETUP > Instrument
Settings > Store Plot
Data
SPECIAL FUNCTIONS >
Set Reference
Settings for saving
tests
24
Table 2. Twisted Pair Test Settings (cont.)
PASS*/FAIL Only: The tester shows HDTDX and HDTDR results only for Autotests with PASS*,
FAIL*, or FAIL results.
All AUTOTESTs: The tester shows HDTDX and HDTDR for all Autotests.
Select Enable to test cabling through an unpowered mid-span PoE (Power over Ethernet)
device. See the Technical Reference Handbook for details.
Standard: The tester displays and saves plot data for frequency-based tests such as NEXT,
return loss, and attenuation. The tester saves data for the frequency range required by the
selected test limit.
Extended: The tester saves data beyond the frequency range required by the selected test
limit.
No: Plot data is not saved, which lets you save more results. Saved results show worst margins
and worst values for each pair.
The tester must be referenced to the smart remote the first time the two units are used
together. You should also set the reference every 30 days. See "Setting the Reference for
Twisted Pair Cabling" on page 20.
See "Preparing to Save Tests" on page 19.
Description