Settings For Fiberinspector Tests - Fluke Versiv User Manual

Cabling certification product family
Hide thumbs Also See for Versiv:
Table of Contents

Advertisement

Versiv Cabling Certification Product Family
Users Manual

Settings for FiberInspector Tests

Table 5 gives descriptions of the settings for FiberInspector tests.
To set up a project, which includes the settings in Table 5, cable
IDs, and operator names, see Chapter 11.
To set up a FiberInspector test
On the home screen, tap the test setup panel.
1
On the CHANGE TEST screen, select a FiberInspector test, then
2
tap EDIT.
Or to set up a new FiberInspector test, tap NEW TEST. If no
module is installed, the MODULE screen shows. Tap
FiberInspector or FI-7000.
On the TEST SETUP screen, tap the panels to change settings
3
for the test. See Table 5.
On the TEST SETUP screen, tap SAVE when your test setup is
4
completed.
On the CHANGE TEST screen, make sure the button next to
5
the test is selected, then tap USE SELECTED.
Table 5. Settings for FiberInspector Tests
Setting
Module
Test Type
Test Limit
84
Select a CertiFiber Pro or OptiFiber Pro module or
FI-7000.
Select FiberInspector.
To give images a PASS or FAIL result manually, select
Manual. Or, select a limit to compare scratches and
defects to specific criteria for size and location.
To see a different group of limits, tap MORE, then tap
the name of a group. To make a custom limit, tap
Custom in the Limit Groups list. See the Technical
Reference Handbook.
Description

Advertisement