Download Print this page

Operation - Siemens SITRANS F M MAG 5000 Instructions Manual

Hide thumbs Also See for SITRANS F M MAG 5000:

Advertisement

Available languages

Available languages

Commissioning
The cleaning unit can be set at:
• Automatic cleaning
Automatic cleaning
Set the relay output of the signal converter at cleaning.
Set the required cleaning cycle time. The default value is 24 hours. Use the lock key to lock the set values.
Return to the operator menu using the top-up key. The signal converter is now set at automatic cleaning.
Technical data
We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full con-
sistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Responsibility for suitability and intended use of
this instrument rests solely with the user.
Copyright © Siemens AG 05.2008 All Rights Reserved. Technical data subject to change without prior notice.
Siemens Flow Instruments A/S
6430 NORDBORG
DENMARK
www.siemens.com/flowdocumentation
Order no.: 083R9148
SFIDK.PI.026.J3.02
Literature no.: SFIDK.PI.026.J3.02
Cleaning voltage
AC cleaning
DC cleaning
Cleaning period
Relay
• Load

Operation

• Automatic
• Manual
Indicator lamps
Supply voltage and power consumption
Ambiens temperature
• During operation
• During storage
Electrical noise (EMC)
Enclosure
• Material
• Width
• Height
• Rating
• Mechanical load
Dimensions
Weight
60 V AC
30 V DC
60 s + 60 s pause period
42 V AC / 2 A; 24 V DC / 1A
Switch relay activated when cleaning is in progress
Yes
No
LEDs: "ON" and "CLEANING"
115 ... 230 V AC, +10% ... -15%, 50 ... 60 Hz, 7 VA cleaning,
5 VA stand by
11 ... 30 V DC / 11 ... 24 V A C, 50 ... 60 Hz, 7 VA cleaning,
5 VA stand by
-20 ... +50°C (-4 ... +122°F)
-20 ... +70°C (-4 ... +158°F)
CENELEC
Light industry
Heavy industry
Standard 19" insert in aluminium/steel (DIN 41494)
21 TE (4.75")
3 HE (5.25")
IP20 / NEMA 2 to EN 60529 and DIN 40050
1 g, 1 ... 800 Hz sinusoidal in all directions to EN 60068-2-36
1 kg
083R9148
Copyright © Siemens AG 03.2009. All rights reserved
Emission
Emmunity
EN 50081-1
EN 50082-2
*083R9148*