Internal heat pump, type AWC-I-M
!
Please note
Avoid damaging the appliance
during handling.
Never load the top, front or
side panels of the appliance.
Requirements of the installation room
&
The installation room must be dry
and safe from the risk of frost.
!
Please note
High floor loading can result
in building damage.
Observe the permissible floor
load.
Preparing for installation
!
Please note
If the compressor is at a steep
angle in the heat pump, lubri-
cant will enter the refrigerant
circuit and damage the appli-
ance.
Never tilt the heat pump more
than 45° during handling and
installation.
Total weight type AWC-I-M: 255 kg
&
To prevent structure-borne noise,
never set up the appliance on ceil-
ings with wooden joists (e.g. in the
attic).
&
Observe minimum clearances.
&
Level the appliance.
&
Required room height at least
2.10 m.
9