System version 2
Required parameter (code to be entered by "Contractor": 5243)
Parameter (ID)
"System definition"
&
"System diagram" (7000)
&
DHW circulation pump
("Wtimer DHW Circ.") (701B)
&
"Vitosolic type"
"Electric heating"
&
"Inst.htg.water heat" (7900)
"Heating circ. A1"
&
"Remote control" (2003)
"Heating circ. M2"
&
"Remote control" (3003)

System version 3

&
The hydraulic diagram shows a
Vitocal 300-A, type AW-O-M.
&
For type AWC-I-M, the secondary
pump and three-way diverter valve
are installed and electrically con-
nected inside the appliance (for
electrical connection, see from
page 71).
&
The appliance starts immediately
after switching on; the insertion of a
jumper in the safety chain is not
required.
(cont.)
Select system diagram 10 (see
page 34 and 132)
&
1 heating circuit without mixer (A1)
&
2 heating circuits with mixer
&
External heat source for heating
and DHW
&
DHW heating with cylinder primary
system
&
Heating water buffer cylinder
&
Swimming pool
Preparing for installation
Setting
"6"
Setting switching times
"1" for Vitosolic 100
"2" for Vitosolic 200
"Yes"
"Yes"
"Yes"