Viessmann VITOCAL 300-A Installation And Service Instructions Manual page 202

Type awc-i-m, aw-o-m compact heat pump with electric drive, 230 v~
Table of Contents

Advertisement

Commissioning/service reports
Control parameters report
Parameter
Electric heating
Max. stage, electric
booster heater
Stage at power-OFF
Hydraulics
Heat pump for drying
buildings
Screed program
Set flow temperature,
external demand
Heating water buffer cylinder
Buffer cylinder
Switching times, buffer
cylinder
Fixed temperature
Hysteresis
Max. temperature
Heating circuits
Room temperature,
standard
Room temperature, re-
duced
Switching times, heat-
ing circuit
Remote control activa-
tion
Heating curve level
Heating curve slope
Room temperature
hook-up slope
Room temperature
hook-up (heating cir-
cuits)
Max. flow temperature
202
(cont.)
Setting range
Yes/No
1 to 3
0 to 3
Yes/No
0 to 12
0 to 70 °C
No/Yes
0 to 3
1 to 70 °C
2 to 20 K
1 to 70 °C
10 to 30 °C
10 to 30 °C
0 to 3
Yes/No
-15 to 40
0 to 3.5
0 to 50
0 to 3
10 to 70 °C
Delivered
Commission-
condition
ing
Yes
3
0
No
0
50 °C
No
2
50 °C
5 K
60 °C
20 °C
16 °C
2
No
0
0.6
10
3
40 °C