Specification
Note
&
The output given is the recom-
mended connected load.
&
The total output of all connected
appliances must not exceed
1000 W. If the total output ≤ 1000 W,
the individual rating of a component
can be greater than specified.
&
The stated current indicates the
max. breaking capacity of the
switching contact (observe the total
current of 5 A).
&
Controls for external heat source
and central fault message are
unsuitable for safety LV.
Connection values of the function components
Components
Circulation pump for cy-
linder heating
Cylinder primary pump
Heating circuit pump A1
Secondary pump
Heating circuit pump M2
DHW circulation pump
(switching times, auxili-
ary output)
Circulation pump for
DHW cylinder (reheat-
ing)
Instantaneous heating
water heater control,
stage 1 (accessory)
Instantaneous heating
water heater control,
stage 2 (accessory)
External heat source
control
Central fault message
Connec-
Connected
tion
load [W]
2X7.10
130
2X8.12
130
2X7.9
100
2X8.7
130
2X8.11
100
2X7.11
50
2X8.13
100
2X8.8
10
2X7.5
10
2X7.1
zero volt
2X7.2
contact
2X7.12
zero volt
2X7.13
contact
Specification
Voltage [V] Max. break-
ing capa-
city [A]
230
4(2)
230
4(2)
230
4(2)
230
4(2)
230
4(2)
230
4(2)
230
4(2)
230
4(2)
230
4(2)
250
4(2)
250
4(2)
203