Compressor enable
The compressor can be permanently
blocked (e.g. operation with only
instantaneous heating water heater,
accessory).
Never block the compressor during
standard mode.
Press the following keys:
1. "Device settings".
2. "Programming".

Heat pump output

Entry of the heat pump output for the
energy statement.
Type
AWC-I-M
AW-O-M
Press the following keys:
1. "Device settings".
2. "Programming".
Temperature for defrost stop
Defrosting is terminated as soon as
the temperature set at the evaporator
for defrost stop is reached. The fan
starts a few seconds before defrost
stop, to remove any remaining water
from the evaporator fins. The diverter
valve changes over to heating mode.
3. "Compressor".
4. y/x for "Enable" (5000).
5. "NO"
6. "YES"
7. "BACK"
3. "Compressor".
4. y/x for "Output" (5030).
Heating output
5. l/m for "10"
in kW
10
6. "BACK"
10
Delivered condition
Setting range
Press the following keys:
1. "Device settings".
2. "Programming".
3. "Compressor".
Compressor control settings
to block the compres-
sor
or
to enable (delivered
condition).
to confirm.
to confirm.
10 kW (set
value)
1 to 255 kW
143