Overview of the PCBs and connection options
Pos. Function
wYI
Central fault message
PCB 2, terminal X8
Pos. Function
End of safety chain
Compressor control via
refrigerant circuit
N/A
Fan control
w¢E
Secondary pump
w¢R
Control of instantaneous
heating water heater,
stage 1
w¢T
Control of the mixer
motor, heating circuit M2,
signal OPEN
w¢Z
Control of the mixer
motor, heating circuit M2,
signal CLOSE
Connection and wiring diagrams
Explanation
Zero volt contact:
&
Closed: Fault
&
Open: No fault
&
Contact breaking capacity
250 V~, 4(2) A
&
Not suitable for safety LV
On-site connection
Explanation
'Live' in case of fault-free safety
chain
&
Heat demand: Contact closed,
2X8.2 is 'live'
&
If the compressor will not
start, check whether it has
been enabled by the refriger-
ant circuit (electronic expan-
sion valve EEV controller)
(own relay on EEV PCB, see
page 178)
Internal connection
N/A
Internal connection
&
In systems without a heating
water buffer cylinder, the sec-
ondary pump is sufficient (see
terminals 2X7.9)
&
Max. output: 130 W
On-site connection
Accessories
&
Output 10 W
On-site connection
&
230 V
On-site connection
&
230 V
On-site connection
(cont.)
Terminals
2X7.12
2X7.13
Terminals
2X8.1
2X8.1
2X8.2
2X8.3
2X8.4
2X8.5
2X8.7
2X8.8
2X8.9
2X8.10
171