Setting Count By ("Cntby") And Decimal Point ("Set Dp") - Omega DP41-B Series User Manual

Universal input
Hide thumbs Also See for DP41-B Series:
Table of Contents

Advertisement

10. Data Format Commands (P, G, R, W)
10.3

SETTING COUNT BY ("CNtby") AND DECIMAL POINT ("SEt dP")

BIT POSITION
7
6
5
4
0
0
0
0
0
1
0
1
0
0
1
1
1
0
0
1
0
1
1
1
0
1
1
1
X
EXAMPLE: To set the meter's display decimal point at the 4th position (FFF.FFF) and
reading value counted by 2:
The command data is 01000001BIN. = 41 HEX. Then send *W0C41
TABLE 10.3 COUNT BY and DECIMAL POINT
3
2
1
0
0
0
0
0
0
1
0
1
0
0
1
1
1
0
0
1
0
1
1
1
0
1
1
1
X
CNtby and SEt dP
001 Count By 1
002 Count By 2
005 Count By 5
020 Count By 10
020 Count By 20
050 Count By 50
100 Count By 100
(Not Used)
(Not Used)
NONE
FFFFFF
FFFFF.F
FFFF.FF
FFF.FFF
FF.FFFF
F.FFFFF
(Not Used)
(Not Used)
10-4