4
Configuring The Meter
4.2 SELECTING A DECIMAL POINT POSITION
Note
To select a decimal point display position, follow these steps:
Press the MENU button until the meter shows DEC.P .
1.
Press the ∂TARE button. The meter shows one of the following:
2.
Press the ßNT/GRS button to scroll between available choices.
3.
Press the MENU button to store your choice. The meter momentarily shows STRD ,
4.
followed by the next menu RD.S.O (Reading Scale and Offset). Or you can press
the RESET button to abort and go back to the DEC.P menu.
4.3 SELECTING READING SCALE AND OFFSET
Note
To scale the meter to show readings in engineering units. There are two methods. One
method is to scale with known inputs. Another method is to scale without known inputs:
you calculate input values based on the transducer specifications and manually enter
them through the keyboard.
22
Refer to Table 6-1 for a summary list of menu configuration.
FFF.F
•
FF.FF
•
F.FFF
•
FFFF ( Default )
•
Refer to Table 6-1 for a summary list of menu configuration.
DEC.P