10. Data Format Commands (P, G, R, W)
10.17 BLOCK A continued
EXAMPLE: To configure meter working with the following order and desired options:
FUNCTIONS
Analog Out Offset
Analog Out Scale
Input Offset
Input Scale
Display Offset
Display Scale
Setpoint 4 Value
Setpoint 3 Value
Setpoint 2 Value
Setpoint 1 Value
The command data is in order as following:
700000A186A07000006186A07000006186A0109C40107530104E20102710
Then send:
*W40700000A186A07000006186A07000006186A0109C40107530104E20102710
DESIRED OPTIONS
0
0.0001
0
1
0
1
+40000.
+30000.
+20000.
+10000.
10-18
EQUIVALENT
HEX VALUE
700000
A186A0
700000
6186A0
700000
6186A0
109C40
107530
104E20
102710