4.2 SELECTING A DECIMAL POINT POSITION (DEC.P)
Refer to Table B-2 for a summary list of menu configuration.
To select a decimal point display position, follow these steps:
1. Press the MENU button until the meter shows "dEc.P".
2. Press the ¢/TARE button. The meter shows one of the following:
*
FFF.F
*
FFFF.
*
FFFF
*
F.FFF
*
FF.FF
3. Press the ¢/TARE button to move the decimal point to the right one
position.
4. Press the MENU button to store your choice. The meter momentarily
shows "Stor", followed by "ScAL" (Scaling).

4.3 SCALING THE METER

There are two scaling methods. One method is internal scaling, "int" (scaling
without known loads): you decide upon low and high reading values and
manually enter them through the keyboard. The meter then operates with those
new parameters. Another method is live scaling, "LivE" : you apply low and
high input signals and change the meter reading accordingly. The meter
calculates a new scale factor and then operates with those new parameters.
14