Omega DP41-B Series User Manual page 92

Universal input
Hide thumbs Also See for DP41-B Series:
Table of Contents

Advertisement

Value -100:
Desired
Values:
ADDRESS
-100
st
1
command
(for absolute
value)
nd
2
command
(for Sign &
dec. point)
Figure 8.5: Write (3 Data bytes) Commands Sample via
8
Diagnostic command.
This command echoes the sent message to indicate that the communication link is
established correctly.
Send to/Return from device:
DEVICE
ADDRESS
1 BYTE
hh
where:
Diagnostic Code is two byte code to determine the type of test to be performed.
o
Universal Input Meters supported only "00" code which requested slave to echo
o
sent command back to the master.
FUNCTION
DEVICE
CODE
06
1 BYTE
1BYTE
01
06
1 BYTE
1BYTE
01
06
Infinity Configuration Software.
FUNCTION
DIAGNOSTIC
CODE
1 BYTE
HB
08
00
DATA
REGISTER
HB
LB
00
01
HB
LB
81
00
LOOPBACK
CODE
LB
HB
00
hh
M - 13
DATA VALUE
(2 bytes used)
HB
LB
00
64
HB
LB
00
90
CRC
DATA
LB
LB
hh
hh
CRC
LB
HB
D8
B4
LB
HB
D8
2E
HB
hh

Advertisement