Ricoh M160 Service Manual page 712

Table of Contents

Advertisement

Bit Switches - 1
No
0B: Switz.
0C: Portugal
0D: Holland
0E: Spain
0F: Israel
10: ---
11: USA
No
Function
Threshold memory level for
0-7
parallel memory transmission
No
Function
TTI printing position
0: Superimposed on the page
0
data
1: Printed before the data
leading edge
1
Not used
TTI used for broadcasting
0: The TTIs selected for each
3
Quick/Speed dial are used
1: The same TTI is used for all
destinations
SM
System Switch 0F (SP No. 1-101-016)
Function
1D: Brazil
20: Turkey
21: Greece
22: Hungary
23: Czech
24: Poland
System Switch 10 (SP No. 1-101-017)
Threshold = N x 128 KB + 256 KB
N can be between 00 - FF(H)
Default setting: 02(H) = 512 KB
System Switch 11 (SP No. 1-101-018)
Change this bit to 1 if the TTI overprints
information that the customer considers to be
important (G3 transmissions).
Do not change this setting.
1: The TTI (TTI_1 or TTI_2) which is selected
for all destinations during broadcasting.
Comments
Comments
Comments
If "1" is selected, it is possible that sent
data is printed on two sheets of paper.
56
M160/M161 Fax Option

Advertisement

Table of Contents
loading

This manual is also suitable for:

M161Sp 4510sfMp 401 spf

Table of Contents