Ricoh M160 Service Manual page 349

Table of Contents

Advertisement

SC No.
Level
SC No.
Level
SC991-00
C
SC No.
Level
SC992-00
D
SM
Error Name/Error Condition/Major Cause/Solution
Incorrect argument
Incorrect internal parameter
Insufficient working memory
Abnormal performance caused by an error that cannot be
detected in normal SC detection due to hardware
specifications.
Turn the main power switch off and on.
Reinstall the software of the controller board.
Reinstall the software of the engine board.
Error Name/Error Condition/Major Cause/Solution
Software continuity error
The software has attempted to perform an unexpected
operation. (However, the process can continue running if
recovery processing is carried out.)
Incorrect argument
Incorrect internal parameter
Insufficient working memory
May have resulted from an error that cannot be detected by
the hardware using normal SC detection.
Not required
Error Name/Error Condition/Major Cause/Solution
Undefined SC error
An error that is not controlled by the system occurred (the error
does not come under any other SC code).
A SC code used in the previous machine was applied
erroneously.
Turn the main power switch off and on.
6-105
Service Call
M160/M161