Ricoh M160 Service Manual page 263

Table of Contents

Advertisement

SC No.
Level
SC554-00
A
SC No.
Level
SC557-00
C
SM
Error Name/Error Condition/Major Cause/Solution
Fusing (End) thermistor high-temperature detected (hardware)
The hardware high-temperature error sensor flag is detected.
Damaged triac (shorted)
Failed engine control board
Failed fusing thermopile
Failed fusing thermistor
Abnormal fusing control software behavior
The PWM signal is continuously supplied from the IH
inverter (due to a software or temperature sensor error).
Clear the SP: fusing SC.
Replace the PSU.
Replace the Engine Board.
Replace the fusing thermopile.
Replace the Fusing Unit.
Error Name/Error Condition/Major Cause/Solution
Zero-crossing frequency exceeded
The number of zero-crossing interrupts exceeds a certain value
in 500 ms.
The frequency of the commercial power supply line is unstable
or noise occurs.
None