Service Call
SC No.
Level
SC835-00
B
[1102]
[110C]
[1120]
SC No.
Level
SC838-00
D
[2701]
M160/M161
Error Name/Error Condition/Major Cause/Solution
Self-diagnostic error: Standard SDRAM DIMM
[XXXX]: Detailed error code
The loopback connector is connected but check results is an
error.
IEEE1284 connector error
Centronic loopback connector defective
Replace the controller board.
The loopback connector is connected but check results is an
error.
ASIC device error
IEEE1284 connector error
Centronic loopback connector is defective
Replace the controller board.
Centronic loopback connector is not connected for detailed
self-diagnostic test.
Centronic loopback connector not connected correctly
Centronic loopback connector is defective
ASIC device is defective
Replace the controller board.
Error Name/Error Condition/Major Cause/Solution
Self-diagnostic Error: Clock Generator
[XXXX]: Detailed error code
A verify error occurred when setting data was read from the
clock generator via the I2C bus.
Defective clock generator
Defective I2C bus
Defective I2C port on the CPU
Replace the controller board.