Ricoh M160 Service Manual page 754

Table of Contents

Advertisement

Bit Switches - 4
No
Function
Alarm when an error occurred
in Phase C or later
0
0: Disabled
1: Enabled
Alarm when the handset is
off-hook at the end of
1
communication
0: Disabled
1: Enabled
2-3
Not used
Sidaa manual calibration
setting
4
0: Off
1: On
6
Not used
SM
G3 Switch 0F (SP No. 1-105-016)
If the customer wants to hear an alarm after each
error communication, change this bit to "1".
If the customer wants to hear an alarm if the
handset is off-hook at the end of fax
communication, change this bit to "1".
Do not change these settings.
1: manually calibrates for communication with a
line whose current change occurs such as an
optical fiber line.
Do not change this setting.
98
Comments
M160/M161 Fax Option

Advertisement

Table of Contents
loading

This manual is also suitable for:

M161Sp 4510sfMp 401 spf

Table of Contents