20 Ohm:
max. 160 m distance AS/IS-VS by 0.6 mm diameter
max. 300 m distance AS/IS-VS by 0.8 mm diameter
supply voltage:
housing:
dimensions (in mm):
weight
acceptable ambient temperature:
degree of protection:
input current, standby
max. input current:
Replace the indoor station – program bell buttons
Basic principle
All devices at the TCS:BUS have a unique serial number.
Programming a bell button means to allocate a serial number of an indoor station to the
bell button of a front-door station. The number is stored in the EEPROM of the front-
door station.
Ensure that the new indoor station is connected to the TCS:BUS and that the mains
voltage is switched on (the operation LED at the power supply and control unit is on).
Further ensure that the access to the flat is granted during the programming.
This instruction describes the case, in which a serial number is allocated to a bell button
and no programming lock is set. To deactivate a programming lock, a Service Device
TCSK-01 or the configuration software configo™ is needed.
TCS TürControlSysteme AG, TCS Hotline Germany: hotline@tcsag.de
FAX: +49(0) 41 94/ 9 88 129
12
AS
front-door station
VS
power supply and control unit
IS
indoor station
FE
extended function
Technical data
+24 V ± 8 % (power supply and control unit)
plastics (colors as given in catalogue)
H 204 (without handset cord) x W 100 x D 50
305 g
-5 ...+ 40 °C
IP30
2-wire operation: I(a) = 0.4 mA
3-wire operation: I(a) = 0.2 mA, I(P) =0.2 mA
I(Pmax) = 60 mA
Repair
Short-circuit
a, b here
Subject to technical changes.
PI_ISH3022-uk