Internal Calls And Control Functions; Simple; On/Off; Send Control Function - TCS Carus Origo CAI2010 Product Information

Video indoor station
Table of Contents

Advertisement

Internal calls and control functions

The plain texts, which should appear in the selection menu, can be set
with the configuration software configo™. Internal call destinations or con-
trol processes can be entered there as plain text.
10 internal calls and 10 control functions can be sent via the OSD menu.

Simple

Each triggering sends the same control protocol. There is no status indi-
cation of the device, which is to be switched. The serial number and the
control function number can be configured as parameter. Thus, it is pos-
sible to automatically generate the unique serial number of the video in-
door station CAI20x0.

ON/OFF

Two different control protocols with the same serial number are sent al-
ternating. One control function number is used for switching on and the
other for switching off. Via two different symbols, which appear inde-
pendently in front of the list entry, the latest switched status can be seen.
The control function number as well as the serial number can be config-
ured here. If required, the device-unique serial number can be generated.

Send control function

Triggering the control function can have three different effects:
 A control protocol is sent (no symbol in the menu).
 Two different control protocols are sent alternately (symbol in the
menu with red/green point). The color of the point indicates the trig-
gered switching process, but not the actual state of the device which is
to be switched.
 A control protocol is sent and the execution of the switching process is
indicated in the menu by a red/green point.
23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Carus origo cai2000

Table of Contents