(3)

Changing IP Address (from factory default: 192.168.0.20 to 192.168.0.21)

Display
(Upper/Lower)
IP
DISP
▽or △ Key
IP 1
192
▽ Key
IP 2
168
▽ Key
IP 3
0
▽ Key
IP 4
20
SET/REC/STOP Key
IP 4
020
↑Blinking
▽or △ Key
IP 4
021
↑Blinking
SET/REC/STOP Key
IP 4
21
▽ Key
Check that SUB1 to SUB4 are set to 255, 255, 255 and 0 respectively and apply them
in the same way as the procedure above.
After the settings for IP 1 to IP 4 and SUB1 to SUB4 are completed, press the
MODE key.
"RESET" is displayed and the unit resets itself.
Display the first segment of the IP address. Press the ▽ or △
key until "P 1" appears at the upper row.
Check that "192" is displayed at the lower row, and press the ▽
key.
If "192" is not displayed, change the value referring to the changing
"IP 4" example shown later.
Check that "168" is displayed at the lower row, and press the ▽
key.
If "168" is not displayed, change the value referring to the changing
"IP 4" example shown later.
Check that "0" is displayed at the lower row, and press the ▽ key.
If "0" is not displayed, change the value referring to the changing
"IP 4" example shown later.
Press the SET/REC/STOP key to change the value displayed at
the lower row to "21".
The value starts blinking. Press the ▽ or △ key to change the
value to "21".
Press the SET/REC/STOP key to apply the value. Blinking stops.
To check or change the subnet mask, press the ▽ key to display
"SUB1" at the upper row.
3-12